Sepahvand A, Salim K, Hoseinzadeh E, Jafari K, Mohammadrezaei Khorramabadi R. Indoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran, 2018. J Environ Health Sustain Dev 2020; 5 (3) :1077-1090
URL: http://jehsd.ssu.ac.ir/article-1-218-en.html
Department of Environmental Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran.
Abstract:   (1789 Views)
Introduction: the aim of this study was to determine the quantity and quality of indoor and outdoor air fungus bioaerosols in Khorramabad day care child centers.
Materials and Methods: A total of 180 air samples were collected from 10 centers in 2018. The samples included 7 indoor and 2 outdoor sampling points. The total number of children was 580. Sampling of fungal bioaerosols was performed by the ZEFON pump (ZEFON factory, USA) with a flow rate of 28.3 L/min. The Sabouraud Dextrose Agar containing chloramphenicol was used as the culture medium. Relative humidity and temperature were measured by a Hygro-Thermometer (TES-1360A- Taiwan-made Humidity and temperature meter).
Results: The results showed that 96.1 % of the samples were positive and had grown colonies. The highest amount of fungal agents in the indoor air and outdoor air were 175.58 CFU/m3 and 274.56 CFU/m3 in May, while the lowest rates were 3.4 CFU/m3 and 7.8 CFU/m3 in July, respectively. Aspergillus niger and Mucor were the most highly abundant fungus genera, while Fusarium was the lowest one. In all samples, the I/O (indoor/outdoor) ratio was more than 1; so, fungal bioaerosols in indoor environments were dominant than the outdoor fungal bioaerosols. The relationship of fungal bioaerosols with RH and T)°C( was significant (P-value = 0.001).
Conclusion: Generally, the amount of contamination is considerable in the studied day care child centers. Therefore, ventilation modification is recommended by a purifier filter. Moreover, the ventilation conditions and favorable air standards should be monitored continuously by supervisory authorities.
Full-Text [PDF 900 kb]   (599 Downloads) |   |   Full-Text (HTML)  (672 Views)  
Type of Study: Original articles | Subject: Air and waste management
Received: 2020/05/28 | Accepted: 2020/07/10 | Published: 2020/09/27

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2015 All Rights Reserved | Journal of Environmental Health and Sustainable Development

Designed & Developed by : Yektaweb