Abstract:   (2039 Views)
Introduction: Hospitals, as one of the important elements in the health system, play an important role in patient’s health. Fungi are one of the effective parameters on indoor air quality. This study aimed to compare of fungal contamination of two hospitals in Shiraz City.
Materials and Methods: Sampling was conducted based on NIOSH 0800 standard (1.5 meters above the ground level with one stage Anderson and Sabaroud dextrose agar enriched chloramphenicol as the growth media) in January-September 2017. The investigated wards included pathological laboratory, emergency rooms, neonatal specialist care, radiology, operating room, and maternity ward. The results showed that the variation and concentration of fungi were higher in hospital X than hospital Y, which was located in an agricultural area far from the city center.
Results: The predominant fungi were Monillia, Aspergillus, and Penicillium in hospital Y, while they were Aspergillus and Penicillium in hospital X. The highest concentrations were found in emergency and laboratory wards. With regard to higher fungal contamination of hospital X and its different location, it can be concluded that the geographical properties and outdoor air are effective factors on indoor air contamination at hospitals.  
Conclusion: Appropriate management of patients' admission and visiting time can be effective on indoor air contamination at hospitals. Furthermore, efficient ventilation using high-efficiency particulate air and appropriate devices for elimination of fungi level are recommended to this end. Moreover, these parameters can provide physical and psychometric health problems for patients’ careers and other health workers.
Full-Text [PDF 565 kb]   (576 Downloads) |   |   Full-Text (HTML)  (820 Views)  
Type of Study: Original articles |
Received: 2019/09/22 | Accepted: 2019/11/20 | Published: 2019/12/21

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2015 All Rights Reserved | Journal of Environmental Health and Sustainable Development

Designed & Developed by : Yektaweb