Vahidmoghadam R, Mirzaei N, Mousavi G, Nazari-Alam A, Nazeri M, Gholipour S, et al . Determining the Concentration of Particulate Matters and Microbiological Quality of Indoor Air in Intensive Care Units of Kashan Hospital, Iran. J Environ Health Sustain Dev 2023; 8 (2) :1975-1987
URL: http://jehsd.ssu.ac.ir/article-1-599-en.html
Department of Environmental Health Engineering, Faculty of Health, Kashan University of Medical Sciences, Kashan, Iran.
Abstract:   (412 Views)
Introduction: Maintaining hospital air quality is very important, especially in intensive care units (ICUs), where patients undergo invasive procedures. Therefore, the present study was conducted with the aim of determining the relationship between particulate matters (PMs) and bioaerosols in pediatric ICU (PICU), neonatal ICU (NICU), and ICU open heart (ICU OH) of Shahid Beheshti Hospital in Kashan.
Materials and Methods: This cross-sectional study was conducted for six consecutive months, i.e., autumn and winter of 2021. PM samples were taken using a Grimm Dust Monitor and microbial samples were taken using a Quick Take 30 sampler. Kolmogorov-Smirnov test was used for analysis and then ANOVA and LSD were used for further tests.
Results: The maximum and minimum PM10 concentrations in the PICU and ICU OH were 59.19 and 9.71 μg/m3, respectively; and the maximum and minimum PM2.5 concentrations were 20.23 μg/m3 in the NICU and 4.69 μg/m3 in PICU. The mean PM concentration and the number of bacterial and fungal colonies were consistent with the WHO and EPA guidelines. Gram-positive Staphylococcus were the most abundant bacteria (90.96%). The most abundant fungi were Aspergillus (54.23%), Penicillium (15.64%), and Cladosperium (12.17%) species. There was also no significant relationship between PMs and bioaerosols.
Conclusion: The mean concentrations of PMs and bioaerosols match with the guidelines, which can be attributed to more observance of health protocols and restrictions on the movement of people into ICUs due to the COVID-19 outbreak.
Full-Text [PDF 715 kb]   (206 Downloads) |   |   Full-Text (HTML)  (241 Views)  
Type of Study: Original articles | Subject: Environmental pollution
Received: 2023/03/2 | Accepted: 2023/05/20 | Published: 2023/06/28

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2015 All Rights Reserved | Journal of Environmental Health and Sustainable Development

Designed & Developed by : Yektaweb