<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Environmental Health and Sustainable Development</title>
<title_fa>مجله بهداشت محیط و توسعه پایدار</title_fa>
<short_title>J Environ Health Sustain Dev</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jehsd.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2476-6267</journal_id_issn>
<journal_id_issn_online>2476-7433</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Investigation of Corrosion and Scaling Potential in Drinking Water in Rafsanjan, Iran</title>
	<subject_fa></subject_fa>
	<subject>Water quality and wastewater treatment and reuse</subject>
	<content_type_fa></content_type_fa>
	<content_type>Original articles</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,&amp;quot;sans-serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;Introduction&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt; Corrosion and scaling are important factors affecting drinking water quality, causing health and economic problems. This study aimed to investigate the indicators of corrosion and scaling in Rafsanjan drinking water.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,&amp;quot;sans-serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;Materials and Methods&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt; The present descriptive cross-sectional study was conducted in winter 2018 and spring 2019 in Rafsanjan.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;The 56 samples were randomly taken from the drinking water distribution and transmission networks. Physicochemical parameters, such as pH, temperature, total dissolved solids (TDS), total hardness (TH), calcium hardness (CH), electrical conductivity (EC), and alkalinity were measured.&amp;nbsp; Finally, corrosion and scaling indices, including langelier index (LI), &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;ryznar &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;index (RI), &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;aggressiveness index (AI), &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;and &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;Puckorius&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt; index (PI) were calculated and analyzed.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:Calibri,&amp;quot;sans-serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;i&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;Results&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;/b&gt;&lt;b&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt; The mean temperature, pH, CH, TH, TDS, alkalinity, and EC were 17.79 &amp;plusmn; 0.80 &amp;deg;C, 8.08 &amp;plusmn; 0.11, 56.34 &amp;plusmn; 2.72 mg/L.CaCO&lt;sub&gt;3&lt;/sub&gt;, 140.86 &amp;plusmn; 6.81 mg/L.CaCO&lt;sub&gt;3&lt;/sub&gt;, 530 &amp;plusmn; 110 mg/L, 181.21 &amp;plusmn; 13.65 mg/L, and 840 &amp;plusmn; 180 &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN-GB&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&amp;micro;s&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;/cm, respectively.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;The mean corrosion and &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;scaling &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;indices, including LI = 0.18 &amp;plusmn; 0.12, RI = 7.72 &amp;plusmn; 0.14, AI = 12.09 &amp;plusmn; 0.11, and finally PI&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt; = &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;7.96 &amp;plusmn; 0.10 were obtained.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:115%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;i&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;Conclusion&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt; Based on the obtained data, drinking water in the transmission and distribution network of Rafsanjan has scaling properties. Water scaling and deposition causes problems, such as blockage of water transmission and distribution pipes, reduction of flow &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;rate&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:10.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt; and increase of pressure drop in the network, and finally increase of water facilities operation costs. Therefore, measures should be considered to control the scaling of water in this region.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Corrosion,Drinking Water,Scaling,Water Quality, Rafsanjan City.</keyword>
	<start_page>1623</start_page>
	<end_page>1631</end_page>
	<web_url>http://jehsd.ssu.ac.ir/browse.php?a_code=A-10-139-5&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Hadi </first_name>
	<middle_name></middle_name>
	<last_name>Eslami </last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>h.eslami1986@gmail.com</email>
	<code></code>
	<orcid>0000-0001-5137-4764</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Health, Occupational Safety and Health Research Center, NICICO, World Safety Organization and Rafsanjan University of Medical Sciences, Rafsanjan, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Fatemeh  </first_name>
	<middle_name></middle_name>
	<last_name>Ayeneh Heidari</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>f.heydary74.fh@gmail.com</email>
	<code></code>
	<orcid>0000-0002-6391-2272</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Student Research Committee, Department of Environmental Health Engineering, School of Health, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Mahnaz</first_name>
	<middle_name></middle_name>
	<last_name>Salari</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahnazslr19@gmail.com</email>
	<code></code>
	<orcid>0000-0003-4275-062X</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Student Research Committee, Department of Environmental Health Engineering, School of Health, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas </first_name>
	<middle_name></middle_name>
	<last_name>Esmaeili </last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>esmailiabbas@yahoo.com</email>
	<code></code>
	<orcid>0000-0001-5364-7949</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Health, Occupational Environment Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Abdolreza </first_name>
	<middle_name></middle_name>
	<last_name>Nassab Hosseini</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>raha_1403@yahoo.com</email>
	<code></code>
	<orcid>0000-0002-3762-2212</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Environmental Health Engineering, School of Health, Occupational Environment Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Maryam</first_name>
	<middle_name></middle_name>
	<last_name>Dolatabadi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dolatabadimaryam222@gmail.com</email>
	<code></code>
	<orcid>0000-0003-3872-0241</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Environmental Science and Technology Research Center, Department of Environmental Health Engineering, School of Public Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran.</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
