Volume 5, Issue 1 (March 2020)                   J Environ Health Sustain Dev 2020, 5(1): 948-954 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Afzal Aghaee M, Rahnama Bargard Z, Nezakati Olfati M R, Ahooey R A, Gohari S. An Adenosine Triphosphate Bioluminescence Method for Evaluating the Microbial Contamination of the Salad-Preparing Tables and Salad-Serving Dishes in Restaurants of Mashhad City, Iran. J Environ Health Sustain Dev 2020; 5 (1) :948-954
URL: http://jehsd.ssu.ac.ir/article-1-209-en.html
Student Research Committee, Mashhad University of Medical Sciences, Mashhad, Iran.
Abstract:   (1566 Views)
Introduction: Consumption of vegetable products is increasing commonly in the world because they are recognized as an important source of nutrients, vitamins, and fiber for humans. Salads are among the most widely used foods that are also known as the most contaminated foods in restaurants. This study was conducted to determine the microbial contamination of salad-preparing tables and salad-serving dishes.
Materials and Methods: This study was conducted at 39 restaurants in Mashhad City in Iran during 2017. In this regard, 78 samples were determined from the salad preparing tables and serving dishes. Samples were tested for cleanliness status using Adenosine Triphosphate (ATP)-bioluminescence method as a rapid test.
 Results: According to the ATP bioluminescence device, 43.6% of the assessed dishes were clean, 38.5 % were dirty, and 17.9 % were not adequately clean. According to the results of ATP bioluminescence device for tables, 23.1 % of the tested tables passed the test, 15.4 % were classified in the caution status, and 61.5% failed.
Conclusion: The ATP method has been widely used, especially in the food industry, as a rapid method for measuring general levels of cleanliness. However, this method is not a reliable replacement for measuring the microbial contamination. The ATP bioluminescence should not be used as a substitute for quantitation of microbial load.
Full-Text [PDF 811 kb]   (563 Downloads) |   |   Full-Text (HTML)  (784 Views)  
Type of Study: Original articles | Subject: Food safety and hygiene
Received: 2019/12/25 | Accepted: 2020/02/20 | Published: 2020/03/20

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2015 All Rights Reserved | Journal of Environmental Health and Sustainable Development

Designed & Developed by : Yektaweb